Study on functional outcome of the proximal humeral internal locking system (PHILOS) for displaced proximal humeral fractures in adults

  • Dr. NV Narasimha Rao Associate Professor, Department of Orthopaedics, GSL Medical College & General Hospital, Rajahmundry, Andhra Pradesh, India
  • Dr. Challa Supradeeptha Associate Professor; Department of Orthopaedics, GSL Medical College & General Hospital, Rajahmundry, Andhra Pradesh, India
Keywords: Proximal Humeral Internal Locking System (PHILOS), Proximal humeral fractures, Constant- Murley score, Neer’s classification

Abstract

Background: The Incidence of trauma related skeletal injuries have been on the rise in recent years and proximal humerus fractures are one of the most common fractures occurring in the human body. Hence the present study was conducted to evaluate the clinical and functional outcome of the proximal humeral internal locking system (PHILOS) technology.The present study was undertaken to assess the functional and radiological outcome of the proximal humeral internal locking system (PHILOS) for displaced proximal humeral fractures in adults.

Method:The present prospective observational study was conducted in adults with proximal humerus fractures admitted to department of orthopedics, GSL Medical College and General hospital Rajahmundry during study period from 1st October 2015 to 31st March 2017. The study was approved by the institute’s ethical committee. Patients were undergo Open reduction internal fixation with philos locking plating for the sustained fracture under general anaesthesia. Post-operative physiotherapy followed according to protocol, to evaluate the functional outcome.

Result: The average age of patients was 44 years. Males were 16 and females were 09. Most common mechanism of injury observed was Road traffic accident in 72%. The Constant- Murley score was significantly improved (p=.000) over the successive follow-up period. 01 (04%) patient had excellent Constant-Murley scores, 11 (44%) patients had good scores, as like 11 (44%) had moderate scores and only 2 (08%) patients had a poor functional outcome.

Conclusion:In conclusion, the proximal humeral locking plate seems to be an adequate device for the fixation of displaced two-part, three-part and four-part proximal humerus fractures. Due to stable fixation, early functional aftercare is possible and allows the patient to regain good shoulder function and resume normal activities much earlier.

Downloads

Download data is not yet available.

References

Court-Brown CM, Garg A, McQueen MM. The epidemiology of proximal humeral fractures. Acta Orthop Scand. 2001;72(4):365-371.

Kristiansen B, Barfod G, Bredesen J, Erin-Madsen J, Grum B, Horsnaes MW, et al. Epidemiology of proximal humeral fractures. Acta Orthop Scand. 1987;58(1):75-77.

Palvanen M, Kannus P, Niemi S, Parkkari J. Update in the epidemiology of proximal humeral fractures. Clin Orthop Relat Res. 2006;442:87-92. doi: 10.1097/01.blo.0000194672.79634.78.

Holloway KL, Bucki-Smith G, Morse AG, Brennan-Olsen SL, Kotowicz MA, Moloney DJ, et al. Humeral Fractures in South-Eastern Australia: Epidemiology and Risk Factors. Calcif Tissue Int. 2015;97(5):453-465. doi: 10.1007/s00223-015-0039-9. Epub 2015 Jul 14.

Sumrein BO, Huttunen TT, Launonen AP, Berg HE, Felländer-Tsai L, Mattila VM. Proximal humeral fractures in Sweden-a registry-based study. Osteoporos Int. 2017;28(3):901-907. doi: 10.1007/s00198-016-3808-z. Epub 2016 Oct 27.

Park C, Jang S, Lee A, Kim HY, Lee YB, Kim TY, et al. Incidence and mortality after proximal humerus fractures over 50 years of age in South Korea: national claim data from 2008 to 2012. J Bone Metab. 2015;22(1):17-21. doi: 10.11005/jbm.2015.22.1.17.

Karl JW, Olson PR, Rosenwasser MP. The Epidemiology of Upper Extremity Fractures in the United States, 2009. J Orthop Trauma. 2015;29(8): e242-244. doi: 10.1097/BOT.0000000000000312.

Lind T, Krøner K, Jensen J. The epidemiology of fractures of the proximal humerus. Arch Orthop Trauma Surg. 1989;108(5):285-287.

Boileau P, Walch G. The three-dimensional geometry of the proximal humerus. Implications for surgical technique and prosthetic design. J Bone Joint Surg Br. 1997;79(5):857-865.

Burkhart KJ, Dietz SO, Bastian L, Thelen U, Hoffmann R, Müller LP. The treatment of proximal humeral fracture in adults. Dtsch Arztebl Int. 2013;110(35–36):591-597. doi: 10.3238/arztebl.2013.0591. Epub 2013 Sep 2.

Zyto K, Ahrengart L, Sperber A, Törnkvist H. Treatment of displaced proximal humeral fractures in elderly patients. J Bone Joint Surg Br. 1997;79(3):412-417.

Koval KJ, Gallagher MA, Marsicano JG, Cuomo F, McShinawy A, Zuckerman JD. Functional outcome after minimally displaced fractures of the proximal part of the humerus. J Bone Joint Surg Am. 1997;79(2):203-207.

Hodgson SA, Mawson SJ, Stanley D. Rehabilitation after two-part fractures of the neck of the humerus. J Bone Joint Surg Br. 2003;85(3):419-422.

McKoy BE, Bensen CV, Hartsock LA. Fractures about the shoulder: conservative management. Orthop Clin North Am. 2000;31(2):205-216. doi: https://doi.org/10.1016/S0030-5898(05)70141-3.

Gaebler C, McQueen MM, Court-Brown CM. Minimally displaced proximal humeral fractures: epidemiology and outcome in 507 cases. Acta Orthop Scand. 2003;74(5):580-585.

Hanson B, Neidenbach P, de Boer P, Stengel D. Functional outcomes after nonoperative management of fractures of the proximal humerus. J Shoulder Elbow Surg. 2009;18(4):612-621. doi: 10.1016/j.jse.2009.03.024.

Poeze M, Lenssen AF, Van Empel JM, Verbruggen JP. Conservative management of proximal humeral fractures: can poor functional outcome be related to standard transscapular radiographic evaluation? J Shoulder Elbow Surg. 2010;19(2):273-281. doi: 10.1016/j.jse.2009.07.066.

Azar FM, Canale ST, Beaty JH. Campbell’s Operative Orthopaedics. 13thed. Elsevier - Health Sciences Division; 2017. 4776 p.

Thanasas C, Kontakis G, Angoules A, Limb D, Giannoudis P. Treatment of proximal humerus fractures with locking plates: a systematic review. J Shoulder Elbow Surg. 2009;18(6):837-844. doi: 10.1016/j.jse.2009.06.004. Epub 2009 Sep 12.

Hirschmann MT, Fallegger B, Amsler F, Regazzoni P, Gross T. Clinical longer-term results after internal fixation of proximal humerus fractures with a locking compression plate (PHILOS). J Orthop Trauma. 2011;25(5):286-293. doi: 10.1097/BOT.0b013e3181f2b20e.

Martetschläger F, Siebenlist S, Weier M, Sandmann G, Ahrens P, Braun K, et al. Plating of proximal humeral fractures. Orthoped. 2012;35(11):e1606-e1612.

Kumar GNK, Sharma G, Sharma V, Jain V, Farooque K, Morey V. Surgical treatment of proximal humerus fractures using PHILOS plate. Chin J Traumatol. 2014;17(5):279-284. doi: https://doi.org/10.3760/cma.j.issn.1008-1275.2014.05.006.

Vijayvargiya M, Pathak A, Gaur S. Outcome Analysis of Locking Plate Fixation in Proximal Humerus Fracture. J Clin Diagn Res. 2016;10(8):RC01-RC05. doi: 10.7860/JCDR/2016/18122.8281.

Misra A, Kapur R, Maffulli N. Complex proximal humerus fractures in adults—a systematic review of management. Injury. 2001;32(5):363-372. doi: 10.1016/S0020-1383(00)00242-4.

Neer CS. Displaced proximal humeral fractures. II. Treatment of three-part and four-part displacement. J Bone Joint Surg Am. 1970;52(6):1090-1103.

Cruickshank D, Lefaivre KA, Johal H, MacIntyre NJ, Sprague SA, Scott T, et al. A scoping review of biomechanical testing for proximal humerus fracture implants. BMC Musculoskelet Disord. 2015;16:175. doi: 10.1186/s12891-015-0627-x.

Pinkowsky GJ, ElAttrache NS, Peterson AB, Akeda M, McGarry MH, Lee TQ. Partial-thickness tears involving the rotator cable lead to abnormal glenohumeral kinematics. J Shoulder Elbow Surg.2017;26(7):1152-1158. doi: 10.1016/j.jse.2016.12.063. Epub 2017 Mar 27.

Jordan RW, Modi CS. A review of management options for proximal humeral fractures. Open Orthop J. 2014; 8:148-156. doi: 10.2174/1874325001408010148.

Gregory TM, Vandenbussche E, Augereau B. Surgical treatment of three and four-part proximal humeral fractures. OrthopTraumatol Surg Res. 2013;99(1):S197-S207. doi: 10.1016/j.otsr.2012.12.006. Epub 2013 Jan 16.

Gerber C, Schneeberger AG, Vinh TS. The arterial vascularization of the humeral head. An anatomical study. J Bone Joint Surg Am. 1990;72(10):1486-1494.

Darder A, Darder A, Sanchis V, Gastaldi E, Gomar F. Four-part displaced proximal humeral fractures: operative treatment using Kirschner wires and a tension band. J Orthop Trauma. 1993;7(6):497-505.

Constant CR, Murley AH. A clinical method of functional assessment of the shoulder. Clin OrthopRelat Res. 1987;214:160-164.

Moeller AD, Thorsen RR, Torabi TP, Bjoerkman A-SD, Christensen EH, Maribo T, et al. The Danish version of the modified Constant-Murley shoulder score: reliability, agreement, and construct validity. J Orthop Sports Phys Ther. 2014;44(5):336-340. doi: 10.2519/jospt.2014.5008. Epub 2014 Mar 27.

Thanasas C, Kontakis G, Angoules A, Limb D, Giannoudis P. Treatment of proximal humerus fractures with locking plates: a systematic review. J Shoulder Elbow Surg. 2009;18(6):837-844. doi: 10.1016/j.jse.2009.06.004. Epub 2009 Sep 12.

Court-Brown CM, Caesar B. Epidemiology of adult fractures: A review. Injury. 2006;37(8):691-697. doi: https://doi.org/10.1016/j.injury.2006.04.130.

Roux A, Decroocq L, El Batti S, Bonnevialle N, Moineau G, Trojani C, et al. Epidemiology of proximal humerus fractures managed in a trauma center. OrthopTraumatol Surg Res. 2012;98(6):715-719. doi: 10.1016/j.otsr.2012.05.013. Epub 2012 Sep 19.

Erasmo R, Guerra G, Guerra L. Fractures and fracture-dislocations of the proximal humerus: A retrospective analysis of 82 cases treated with the Philos(®) locking plate. Injury. 2014;45(6):S43-S48. doi: 10.1016/j.injury.2014.10.022. Epub 2014 Nov 4.

Menendez ME, Ring D. Does the timing of surgery for proximal humeral fracture affect inpatient outcomes? J Shoulder Elbow Surg. 2014;23(9):1257-1262. doi: 10.1016/j.jse.2014.03.010. Epub 2014 Jun 9.

Buecking B, Mohr J, Bockmann B, Zettl R, Ruchholtz S. Deltoid-split or deltopectoral approaches for the treatment of displaced proximal humeral fractures? Clin OrthopRelat Res. 2014;472(5):1576-1585. doi: 10.1007/s11999-013-3415-7. Epub 2013 Dec 11.

Waliullah S, Kumar A. Difference between radiological and functional outcome with deltoid-splitting approach versus deltopectoral approach for the management of proximal humeral fractures with philos plate. J Orthopaed All Sci. 2013;1(1):14-17. doi: 10.4103/2319-2585.117382.

Thyagarajan DS, Haridas SJ, Jones D, Dent C, Evans R, Williams R. Functional outcome following proximal humeral interlocking system plating for displaced proximal humeral fractures. Int J Shoulder Surg. 2009;3(3):57-62. doi: 10.4103/0973-6042.59971.

Geiger EV, Maier M, Kelm A, Wutzler S, Seebach C, Marzi I. Functional outcome and complications following PHILOS plate fixation in proximal humeral fractures. Acta Orthop Traumatol Turc. 2010;44(1):1-6. doi: 10.3944/AOTT.2010.2270.

Handschin AE, Cardell M, Contaldo C, Trentz O, Wanner GA. Functional results of angular-stable plate fixation in displaced proximal humeral fractures. Injury. 2008;39(3):306-313. doi: 10.1016/j.injury.2007.10.011.

Aksu N, Göğüş A, Kara AN, Işiklar ZU. Complications encountered in proximal humerus fractures treated with locking plate fixation. Acta Orthop Traumatol Turc. 2010;44(2):89-96. doi: 10.3944/AOTT.2010.2313.

Fazal MA, Haddad FS. Philos plate fixation for displaced proximal humeral fractures. J Orthop Surg (Hong Kong). 2009;17(1):15-18. doi: https://doi.org/10.1177/230949900901700104.

Kettler M, Biberthaler P, Braunstein V, Zeiler C, Kroetz M, Mutschler W. [Treatment of proximal humeral fractures with the PHILOS angular stable plate. Presentation of 225 cases of dislocated fractures]. Unfallchirurg. 2006;109(12):1032-1040. doi: https://doi.org/10.1007/s00113-006-1165-7.

Moonot P, Ashwood N, Hamlet M. Early results for treatment of three- and four-part fractures of the proximal humerus using the PHILOS plate system. J Bone Joint Surg Br. 2007;89(9):1206-1209. doi: https://doi.org/10.1302/0301-620X.89B9.18528.

Brunner F, Sommer C, Bahrs C, Heuwinkel R, Hafner C, Rillmann P, et al. Open reduction and internal fixation of proximal humerus fractures using a proximal humeral locked plate: a prospective multicenter analysis. J Orthop Trauma. 2009;23(3):163-172. doi: 10.1097/BOT.0b013e3181920e5b.

Doshi C, Sharma GM, Naik LG, Badgire KS, Qureshi F. Treatment of proximal humerus fractures using PHILOS plate. Journal of clinical and diagnostic research: JCDR. 2017;11(7):RC10-RC13. doi: 10.7860/JCDR/2017/26782.10304.

Manek V, Venkatachalam K, Reddy V. Proximal humeral internal locking osteosynthesis for surgical fixation for displaced two part to four part fractures: A prospective study. Int J Orthopaed. 2018;4(2):640-648. doi: https://doi.org/10.22271/ortho.2018.v4.i2j.93.

Iacobellis C, Fountzoulas K, Aldegheri R. Plating of proximal fracture of the humerus: a study of 30 cases. Musculoskel Surg. 2011;95(1):43-48. doi: 10.1007/s12306-011-0103-1. Epub 2011 Mar 4.

CITATION
DOI: 10.17511/ijoso.2019.i05.07
Published: 2019-12-26
How to Cite
Rao, N. N., & Dr. Challa Supradeeptha. (2019). Study on functional outcome of the proximal humeral internal locking system (PHILOS) for displaced proximal humeral fractures in adults. Surgical Review: International Journal of Surgery, Trauma and Orthopedics, 5(5), 355-364. https://doi.org/10.17511/ijoso.2019.i05.07